| Outdoor Broadband Triplexer | TPO-697136-xxx |
|||
![]() |
|
Overview
|
The CCI Outdoor Broadband Triplexer combines the frequency ranges 555-960 MHz, 1695-2200 MHz, and 2305-2690 MHz onto a common port. Specifically intended for use in multi-band systems with limited feeder lines, this CCI Triplexer facilitates the addition of new technologies including LTE and new spectrum onto existing sites, while providing a high degree of isolation between systems. Decreasing the number of feeder lines lowers tower loading, leasing and installation expenditures and the total cost to upgrade a site is significantly reduced. An optional twin unit with two Triplexers mounted on a single bracket is also available. Technical Description: The Outdoor Broadband Triplexer consists of multiple filters and can be used as either a splitter or combiner to aggregate the 600/700/850/900 bands on port 1, the AWS/PCS bands on port 2, and the WCS/BRS bands on port 3 onto a common feeder line. The fully weatherproof tower mount outdoor Triplexer provides DC and AISG signal pass-through on any of the band specific ports, enabling power and control for TMA's & RET antennas. The Smart Bias-Tee architecture passes the DC and AISG carrier frequency from any one of the input ports to the common port while blocking the DC and AISG signals from being re-injected into the other input ports. The Triplexer has internal multi-strike lightning protection using a multi-stage surge protection circuit. |
Electrical Specification
| RF Parameters | Ports | Frequency(MHz) | Specification |
| Return Loss | Common | 555 - 960 | 18 dB minimum, 20 dB typical |
| 1695 - 2200 | 18 dB minimum, 20 dB typical | ||
| 2305 - 2690 | 18 dB minimum, 20 dB typical | ||
| 600/700/850/900 | 555 - 960 | 18 dB minimum, 20 dB typical | |
| AWS/PCS | 1695 - 2200 | 18 dB minimum, 20 dB typical | |
| WCS/BRS | 2305 - 2690 | 18 dB minimum, 20 dB typical | |
| Insertion Loss | COMMON to 600/700/850/900 | 555 - 960 | 0.15 typical, 0.2 dB maximum |
| COMMON to AWS/PCS | 1695 - 2200 | 0.2 dB typical, 0.35 dB maximum | |
| COMMON to WCS/BRS | 2305 - 2690 | 0.2 dB typical, 0.35 dB maximum | |
| Isolation | COMMON to 600/700/850/900 | 1695 - 2200 | 50 dB minimum |
| 2305 - 2690 | 50 dB minimum | ||
| COMMON to AWS/PCS | 555 - 960 | 50 dB minimum | |
| 2305 - 2690 | 50 dB minimum | ||
| COMMON to WCS/BRS | 555 - 960 | 50 dB minimum | |
| 1695 - 2200 | 50 dB minimum |
| General Characteristics | |
| Impedance | 50 ohms |
| Continuous Average Power | 300 W max. |
| Peak Envelope Power | 5 kW max. |
| IM Performance(all ports) | <-117 dBm (-160 dBc) typical (2× +43 dBm tones) all bands |
| DC Pass Current/AISG Pass | 3A/AISG signal (2.176 Mhz) per AISG 2.0 |
Mechanical Specification
| Model | Single | Twin |
| Connectors | 4 × 7-16 DIN female or 4 × 4.3-10 female |
8 × 7-16 DIN female or 8 × 4.3-10 female |
| Dimensions w/Bracket | 10.09 × 8.27 × 3.13 in. (256.2 × 210.0 × 79.4 mm) |
10.09 × 8.76 × 5.88 in. (256.2 × 222.5 × 149.4 mm) |
| Housing Dimensions | 6.16 × 8.27 × 2.59 in. (156.4 × 210.0 × 65.8 mm) |
6.16 × 8.27 × 5.35 in. (156.4 × 210.0 × 135.8 mm) |
| Weight | 8.3 lbs (3.78 kg) | 16.06 lbs (7.3 kg) |
| Frontal Wind Load | 111.3 N @150km/hour | 111.3 N @150km/hour |
| Lateral Wind Load | 35.0 N @150km/hour | 70.0 N @150km/hour |
![]() |
|
| Single Outdoor Broadband Triplexer Outline Drawing | |
![]() |
|
| Twin Outdoor Broadband Triplexer Outline Drawing |
Parts & Accessories
| TPO-697136-x-S1 | Outdoor Triplexer with 7-16 connectors |
| TPO-697136-x-S2 | Outdoor Triplexer with 4.3-10 connectors |
| TPO-697136-x-T1 | Outdoor Twin Triplexer with 7/16 connectors |
| TPO-697136-x-T2 | Outdoor Twin Triplexer with 4.3-10 connectors |
| Option (-x) | Description |
| -S | Smart Bias-T, DC/AISG Pass through on either port |
| -0 | No DC/AISG Pass through |
| -1 | DC/AISG Pass through Low Band to COMMON, DC Block on all other input ports |
| -2 | DC/AISG Pass through AWS/PCS Band to COMMON, DC Block on all other input ports |
| -3 | DC/AISG Pass through WCS/BRS to COMMON, DC Block on all other input ports |
Standards & Compliance
| Safety | EN 60950-1, UL 60950-1 |
| Emission | EN 55022 |
| Immunity | EN 55024 |
| Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|
|
Pattern Viewer