The CCI Outdoor Broadband Triplexer combines the frequency ranges 390-960 MHz, 1710-2180 MHz, and 2300-2700 MHz onto a common port. Specifically intended for use in multi-band systems with limited feeder lines, this CCI Triplexer facilitates the addition of new technologies including LTE and new spectrum onto existing sites, while providing a high degree of isolation between systems. Decreasing the number of feeder lines lowers tower loading, leasing and installation expenditures and the total cost to upgrade a site is significantly reduced. An optional twin unit with two Triplexers mounted on a single bracket is also available. Technical Description: The Outdoor Broadband Triplexer consists of multiple filters and can be used as either a splitter or combiner to aggregate the 390-960 band on port 1, the 1695-2200 band on port 2, and the 2300-2700 band on port 3 onto a common feeder line. The fully weatherproof tower mount outdoor Triplexer provides DC and AISG signal pass-through, enabling power and control for TMA's & RET antennas. The Triplexer is available with DC/AISG pass options including a Smart DC with autosense. The Smart Bias-Tee architecture passes the DC and AISG carrier frequency from any one of the input ports to the common port while blocking the DC and AISG signals from being re-injected into the other input ports. The Triplexer has internal multi-strike lightning protection using a multi-stage surge protection circuit. |
Electrical Specification
RF Parameters | Ports | Frequency(MHz) | Specification |
Return Loss | 4 (Common) | 390 - 960 | 18 dB minimum, 20 dB typical |
2300 - 2700 | 18 dB minimum, 20 dB typical | ||
1695 - 2200 | 18 dB minimum, 20 dB typical | ||
1 (390-600 /700/800/900) | 390 - 960 | 18 dB minimum, 20 dB typical | |
2 (DCS/IMT2100) | 1695 - 2200 | 18 dB minimum, 20 dB typical | |
3 (2300-2700) | 2300 - 2700 | 18 dB minimum, 20 dB typical | |
Insertion Loss | 4 to 1 (COMMON to 390-600 /700/800/900) | 390 - 960 | 0.3 dB maximum |
4 to 2 (COMMON to 1695-2200) | 2300 - 2700 | 0.3 dB maximum | |
4 to 3 (COMMON to 2300-2700) | 1695 - 2200 | 0.3 dB maximum | |
Isolation | 4 to 1 (COMMON to 390-600 /700/800/900) | 1695 - 2200 | 50 dB minimum |
2300 - 2700 | 50 dB minimum | ||
4 to 2 (COMMON to 1695-2200) | 390 - 960 | 50 dB minimum | |
2300 - 2700 | 50 dB minimum | ||
4 to 3 (COMMON to 2300-2700) | 390 - 960 | 50 dB minimum | |
1695 - 2200 | 50 dB minimum | ||
Group Delay | COMMON to 390-600 /700/800/900 | 390 - 960 | 7 ns maximum |
COMMON to 1695-2200 | 1695 - 2200 | 15 ns maximum | |
COMMON to 2300-2700 | 2300 - 2700 | 17 ns maximum | |
Group Delay Variation | COMMON to 390-600 /700/800/900 | 390 - 960 | 4 ns maximum |
COMMON to 1695-2200 | 1695 - 2200 | 5 ns maximum | |
COMMON to 2300-2700 | 2300 - 2700 | 7 ns maximum |
DC/AISG | |||
DC Autosense | DC path is automatically determined, when the unit is used as a combiner or splitter | ||
Combine Mode Priority | 1. 1710 - 1880 MHz 2. 2300 - 2700 MHz 3. 1920 - 2170 MHz 4. 690 - 960 MHz |
||
DC Autosense Combine Mode (Operation) | The port with dC voltage (7 to 30 V) is automatically passed to the COMMON Port. If more than one port has DC voltage present, the port with the highest priority is passed. If a short circuit is detected on the COMMON Port DC/AISG is disabled for the entire unit. |
||
DC Autosense Splitter Mode (Operation) | DC/AISG pass through will be disabled for ports where a short circuit is detected and DC/AISG will be passed to all other ports. | ||
DC Bypass Power-Up to Operating Time | <100 ms | ||
Current Consumption @ TBD voltage | 35 mA typical, 50 mA maximum (7.0 to 30 VDC) | ||
Current (Single Path) | 2.5 A maximum | ||
Current Common | 2.5 A maximum | ||
AISG signal | 2.176 MHz, per AISG 2.0 |
General Characteristics | |
Impedance | 50 ohms |
Continuous Average Power | 200 W (+53 dBm) maximum per port |
Peak Envelope Power | 2 kW (+63 dBm) maximum per port |
IM Performance(all ports) | <-117 dBm (-160 dBc) typical (2× +43 dBm tones) all bands |
Mechanical Specification
Model | TPO-392226-S-Sx (3 In, 1 Out) | TPO-392226-S-Tx (6 In, 2 Out) |
Modularity | Single | Twin |
Ports, In-Line | 3 x BTS, 1 x ANT | 6 x BTS, 2 x ANT |
Connectors | 4 × 4.3-10 female | 8 × 4.3-10 female |
Dimensions w/Bracket | 10.08 × 5.79 × 2.60 in. (256.0 × 147.0 ×66 mm) |
10.08 × 5.79 × 4.65 in. (256.0 × 147.0 × 118 mm) |
Housing Dimensions | 6.61 × 5.79 × 2.01 in. (168.0 × 147.1 × 51.0 mm) - per Triplexer | |
Weight | 4.85 lbs (2.2 kg) | 9.7 lbs (4.4 kg) |
Housing Ground Lug | 1 x M8 | 1 x M8 |
Finish | Housing - Powder Coat Gray; Bracket(s) - 304 Stainless Steel (Passivated per ASTM A-967) |
|
Packaging Size | TBD | 17.91 x 12.4 x 13.78 in. (455 x 315 x 350 mm) for 4 pcs. |
Packagiing Weight | TBD | 50.6 Lbs. (23 kg) for 4 pcs. |
Available Mast Diameter | 3 to 6 inches (76.2 to 152.4 mm) | |
Pole Mounting | Use integral mouting bracket and the 2 band clamps provided (Orientation, the connectors will be in-line with mast) |
|
Wall Mounting | Use integral mouting bracket and appropriate fasteners (Orientation, no restrictions) |
Outdoor Broadband Triplexer Outline Drawing |
Standards & Compliance
Safety | EN 60950-1, UL 60950-1 |
Emission | EN 55022 |
Immunity | EN 55024 |
Environmental | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-5, IEC 60068-2-6, IEC-60068-2-11, IEC 60068-2-14, IEC 60068-2-18, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-02-30, IEC 60068-2-52, IEC 60068-2-64, IEC61000-4-5, GR-63-CORE 4.3.1, EN 60529 IP67, IP68 |
|